Back to results
Bibliographic record · Consultation and access
Artículo

Accuracy of a flash glucose monitoring system in cats and determination of the time lag between blood glucose and interstitial glucose concentrations

Francesca Del Baldo et al · Oxford University Press · 2021

Supplementary material available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.
Serial publication

A de novo nonsense variant in the DMD gene associated with X‐linked dystrophin‐deficient muscular dystrophy in a cat

This serial publication contains 149 related contents.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Supplementary material available

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Open material

Summary

Descripción general del contenido del recurso.

Abstract Background The FreeStyle Libre (Abbott Laboratories) is a flash glucose monitoring system (FGMS) that measures interstitial glucose concentration (IG). The system is factory‐calibrated, easy to use, inexpensive, and could be useful for monitoring diabetic cats. Objectives To evaluate the analytical and clinical accuracy of the FGMS in cats and establish the lag‐time between IG and blood glucose concentration (BG). Animals Twenty client‐owned diabetic cats and 7 purpose‐bred healthy cats. Methods Prospective study. Blood glucose concentration was measured using a portable glucose meter validated for use in cats that served as a reference method for IG, as measured by FGMS. In diabetic cats, data were collected for sensor wearing time with different methods of application and accuracy across glycemic ranges. Accuracy was determined by fulfillment of ISO15197:2013 criteria. In healthy cats, lag‐time between IG and BG was established after IV administration of exogenous glucose. Results Good agreement between IG and BG was obtained (r = .93). Analytical accuracy was not achieved, whereas clinical accuracy was demonstrated with 100% of the results in zones A + B of the Parkes consensus error grid analysis. In the immediate 30 minutes after an IV bolus of glucose, when BG was increasing rapidly (approximately 2%/min), IG increased slowly, resulting in a difference of as much as 579 mg/dL, and no positive correlation between BG and IG was found. Conclusions and Clinical Importance The FGMS did not fulfill ISO requirements but is sufficiently accurate for glucose monitoring in cats, while considering the lag between IG and BG during periods of rapid changes in BG.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, F. D. B. E. (2021). Accuracy of a flash glucose monitoring system in cats and determination of the time lag between blood glucose and interstitial glucose concentrations. https://doi.org/10.1111/jvim.16122

MLA

al, Francesca Del Baldo et. "Accuracy of a flash glucose monitoring system in cats and determination of the time lag between blood glucose and interstitial glucose concentrations." 2021. https://doi.org/10.1111/jvim.16122.

Chicago

al, Francesca Del Baldo et. 2021. "Accuracy of a flash glucose monitoring system in cats and determination of the time lag between blood glucose and interstitial glucose concentrations.". https://doi.org/10.1111/jvim.16122.

Harvard

al, F. D. B. E. 2021, Accuracy of a flash glucose monitoring system in cats and determination of the time lag between blood glucose and interstitial glucose concentrations, Oxford University Press, available at: https://doi.org/10.1111/jvim.16122 [Accessed 8 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Accuracy of a flash glucose monitoring system in cats and determination of the time lag between blood glucose and interstitial glucose concentrations
Author / contributors
Francesca Del Baldo et al
Publisher
Oxford University Press
Publication year
2021
ISSN
0891-6640
ISSN
0891-6640
Language
English

Subjects

Explore related resources through these subjects.

Copied