Back to results
Bibliographic record · Consultation and access
Artículo

Diode Laser Irradiation in Endodontic Therapy through Cycles - in vitro Study

Trišić Dijana et al · Balkan Stomatological Society · 2017

Supplementary material available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Supplementary material available

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Open material

Summary

Descripción general del contenido del recurso.

Background/Aim: The aim of this in vitro study was to investigate the influence of irradiation cycles and resting periods, on thermal effects on the external root surface during root canal irradiation of two diode laser systems (940 nm and 975 nm), at output powers of 1 W and 2 W in continuous mode. In previous studies the rising of temperature above 7°C has been reported as biologically accepted to avoid periodontal damage on the external root surface. Material and Methods: Twenty human inferior incisors were randomly distributed into four groups, the 940 nm, and the 975 nm diode laser irradiation, both with an output power of 1 W and 2 W, in continuous mode. The thermographic camera was used to detect temperature variations on the external root surface. Digital radiography of the samples was made. Results: After three cycles of irradiation, at apical third of the root, mean temperature variation by 940 nm diode laser irradiation was 2.88°C for output power of 1 W, and 6.52°C for output power of 2 W. The 975 nm laser caused a higher temperature increase in the apical region, with temperature variation of 13.56°C by an output power of 1 W, and 30.60°C at 2 W, with a statistical significance of p ≤ 0.0001 between two laser systems compared for the same power. The resting periods of 20 s between cycles were enough to lower temperature under 7°C in the case of 1 W and 2 W for 940 nm diode laser, while for 975 nm laser, after three irradiation cycles overheating occurred at both output power rates. Conclusion: Three cycles irradiation of 940 nm diode laser, with resting periods of 20 seconds, allowed safe usage of 1 W and 2 W in CW for endodontic treatment. For 975 nm at a power rate of 1 W, the last resting period drop the temperature near the safe limit and it came under 7°C in a period less than a minute, while at the power of 2 W the resting periods were not long enough for the safe temperature decrease.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, T. D. E. (2017). Diode Laser Irradiation in Endodontic Therapy through Cycles - in vitro Study. https://doi.org/10.1515/bjdm-2017-0016

MLA

al, Trišić Dijana et. "Diode Laser Irradiation in Endodontic Therapy through Cycles - in vitro Study." 2017. https://doi.org/10.1515/bjdm-2017-0016.

Chicago

al, Trišić Dijana et. 2017. "Diode Laser Irradiation in Endodontic Therapy through Cycles - in vitro Study.". https://doi.org/10.1515/bjdm-2017-0016.

Harvard

al, T. D. E. 2017, Diode Laser Irradiation in Endodontic Therapy through Cycles - in vitro Study, Balkan Stomatological Society, available at: https://doi.org/10.1515/bjdm-2017-0016 [Accessed 6 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Diode Laser Irradiation in Endodontic Therapy through Cycles - in vitro Study
Author / contributors
Trišić Dijana et al
Publisher
Balkan Stomatological Society
Publication year
2017
ISSN
2335-0245
ISSN
2335-0245
Language
English

Subjects

Explore related resources through these subjects.

Copied