Back to results
Bibliographic record · Consultation and access
Artículo

Detecção e exérese de lesões mamárias não palpáveis orientadas por cirurgia radioguiada com injeção de ar para controle radiológico Detection and excision of non-palpable breast lesions by radioguided surgery and air injection for radiological control

Rafael Henrique Szymanski Machado et al · Federação Brasileira das Sociedades de Ginecologia e Obstetrícia · 2005

Supplementary material available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.
Serial publication

A FEBRASGO e o Novo Ano

This serial publication contains 195 related contents.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Supplementary material available

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Open material

Summary

Descripción general del contenido del recurso.

OBJETIVO: avaliar a eficiência da localização e exérese por cirurgia radioguiada de lesões ocultas mamárias utilizando radiofármaco injetado diretamente no interior das lesões ou até dois centímetros destas com posterior injeção de ar como controle radiológico. MÉTODOS: vinte e nove pacientes com 32 lesões mamárias ocultas, detectadas por mamografia ou ultra-sonografia, classificadas como Bi-Rads® 3, 4 e 5 foram incluídas neste estudo observacional com resultados expressos em percentagens. O radiofármaco utilizado foi o macroagregado de albumina marcado com tecnécio-99m (99mTc-MAA) injetado por orientação mamográfica ou guiado por ultra-sonografia. A injeção do radiofármaco foi seguida pela imediata administração de ar, através da agulha da estereotaxia, visando o controle radiológico da injeção do radiofármaco. A biopsia excisional foi feita com o auxílio do aparelho portátil gamma-probe (detector de radiação gama) e a remoção completa das lesões foi verificada pela radiografia das peças cirúrgicas ou por exame por congelação intra-operatório. RESULTADOS: câncer de mama foi encontrado em 10% (1/10) das lesões BI-RADS® 3, em 31,5% (6/19) das BI-RADS® 4 e em 66,6% (2/3) das BI-RADS® 5. As 29 pacientes corresponderam a 32 espécimes, cirúrgicos. O radiofármaco foi corretamente posicionado em 96,8% (31/32) dos espécimes permitindo remoção de 96,8% das lesões mamárias não palpáveis estudadas. A completa remoção da lesão foi demonstrada pela radiografia das peças em 23 casos (71,8%), pelo estudo intra-operatório por congelação em 21,8% (7/32) e por ambos os métodos em 6,2% (2/32). CONCLUSÃO: a cirurgia radioguiada é importante instrumento na remoção de lesões mamárias não palpáveis, tratando-se de método simples, rápido e exeqüível que pode ser implementado na rotina clínica dessas pacientes.<br>PURPOSE: to asses the efficiency of the radioguided localization and removal of occult breast lesions using radiopharmaceuticals injected directly into the lesions or close to them with posterior air injection as a radiological control. METHODS: twenty-nine consecutive patients with thirty-two occult breast lesions detected mammographically or by ultrasound, and categorized 3, 4 and 5 BI-RADS®, were included in this observational study with results expressed in percentages. The radiopharmaceutical used was human serum albumin labeled with 99mTc-HSA injected inside or close to the lesion using mammographic or ultrasonographic guidance. The injection of the radiopharmaceutical was followed immediately by air injection through the needle used for stereotaxis as a radiological control of the radiopharmaceutical placement. The excision biopsy was carried out with the aid of a hand-held gamma-detecting probe and the entire removal of the lesion was verified by X-ray of the surgical specimens or by intraoperative frozen section examination. RESULTS: breast cancer was found in 10.0% (1/10) of the 3 BI-RADS® lesions, in 31.5% (6/19) of the 4 BI-RADS® and in 66.6% (2/3) of the 5 BI-RADS®. The radiotracer was correctly positioned in 96.8% of the specimens (31/32) allowing the removal of also 96.8% of the studied non-palpable breast lesions. To show the entire removal, X-ray was used in 23 cases (71.8%), intraoperative frozen section study in 21.8% (7/32) and both methods in 6.2% (2/32). CONCLUSIONS: radioguided surgery showed to be an important tool in the removal of non-palpable breast lesions, as a simple, fast and feasible method that can be implemented in the clinical routine of these patients.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, R. H. S. M. E. (2005). Detecção e exérese de lesões mamárias não palpáveis orientadas por cirurgia radioguiada com injeção de ar para controle radiológico Detection and excision of non-palpable breast lesions by radioguided surgery and air injection for radiological control. https://doi.org/10.1590/S0100-72032005001100003

MLA

al, Rafael Henrique Szymanski Machado et. "Detecção e exérese de lesões mamárias não palpáveis orientadas por cirurgia radioguiada com injeção de ar para controle radiológico Detection and excision of non-palpable breast lesions by radioguided surgery and air injection for radiological control." 2005. https://doi.org/10.1590/S0100-72032005001100003.

Chicago

al, Rafael Henrique Szymanski Machado et. 2005. "Detecção e exérese de lesões mamárias não palpáveis orientadas por cirurgia radioguiada com injeção de ar para controle radiológico Detection and excision of non-palpable breast lesions by radioguided surgery and air injection for radiological control.". https://doi.org/10.1590/S0100-72032005001100003.

Harvard

al, R. H. S. M. E. 2005, Detecção e exérese de lesões mamárias não palpáveis orientadas por cirurgia radioguiada com injeção de ar para controle radiológico Detection and excision of non-palpable breast lesions by radioguided surgery and air injection for radiological control, Federação Brasileira das Sociedades de Ginecologia e Obstetrícia, available at: https://doi.org/10.1590/S0100-72032005001100003 [Accessed 10 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Detecção e exérese de lesões mamárias não palpáveis orientadas por cirurgia radioguiada com injeção de ar para controle radiológico Detection and excision of non-palpable breast lesions by radioguided surgery and air injection for radiological control
Author / contributors
Rafael Henrique Szymanski Machado et al
Publisher
Federação Brasileira das Sociedades de Ginecologia e Obstetrícia
Publication year
2005
ISSN
0100-7203
ISSN
0100-7203
Language
English
Copied