Back to results
Bibliographic record · Consultation and access
Artículo

Gas Leakage Detection and Pressure Difference Identification by Asymmetric Differential Pressure Method

Yan Shi et al · KeAi Communications Co., Ltd · 2022

Supplementary material available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Supplementary material available

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Open material

Summary

Descripción general del contenido del recurso.

Abstract Currently, the measurement methods for pneumatic system leakage include bubbling, ultrasonic, and pressure detection methods. These methods are sensitive to high-precision sensors, long detection times, and stable external environments. The traditional differential pressure method involves severe differential pressure fluctuations caused by environmental pressure fluctuations or electromagnetic noise interference of sensors, leading to inaccurate detection. In this paper, a differential pressure fitting method for an asymmetric differential pressure cylinder is proposed. It overcomes the limitation of the detection efficiency caused by the asynchronous temperature recovery of the two chambers in the asymmetric differential pressure method and uses the differential pressure substitution equation to replace the differential calculation of the differential pressure. The improved differential pressure method proposes an innovation based on the detection principle and calculation method. Additionally, the influence of the parameters in the differential pressure substitution equation on the leakage calculation results was simulated, and the specific physical significance of the parameters of the differential pressure substitution equation was explained. The experiments verified the fitting effect and proved the accuracy of this method. Compared with the traditional differential pressure method, the maximum leakage deviation of inhibition was 0.5 L/min. Therefore, this method can be used to detect leaks in air tanks.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, Y. S. E. (2022). Gas Leakage Detection and Pressure Difference Identification by Asymmetric Differential Pressure Method. https://doi.org/10.1186/s10033-022-00697-1

MLA

al, Yan Shi et. "Gas Leakage Detection and Pressure Difference Identification by Asymmetric Differential Pressure Method." 2022. https://doi.org/10.1186/s10033-022-00697-1.

Chicago

al, Yan Shi et. 2022. "Gas Leakage Detection and Pressure Difference Identification by Asymmetric Differential Pressure Method.". https://doi.org/10.1186/s10033-022-00697-1.

Harvard

al, Y. S. E. 2022, Gas Leakage Detection and Pressure Difference Identification by Asymmetric Differential Pressure Method, KeAi Communications Co, Ltd, available at: https://doi.org/10.1186/s10033-022-00697-1 [Accessed 7 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Gas Leakage Detection and Pressure Difference Identification by Asymmetric Differential Pressure Method
Author / contributors
Yan Shi et al
Publisher
KeAi Communications Co., Ltd
Publication year
2022
ISSN
1000-9345
ISSN
1000-9345
Language
English

Subjects

Explore related resources through these subjects.

Copied