Back to results
Bibliographic record · Consultation and access
Document

Automatic detection of reverse‑triggering related asynchronies during mechanical ventilation in ARDS patients using flow and pressure signals

Rodríguez, Pablo Oscar et al · RI ITBA · 2020

Open-access full text
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.

Resource access

Open the content from the main option or choose another available source.

RI ITBA RI ITBA OAI-PMH
Entrar por RI ITBA
Main access

Open-access full text

Texto completo identificado como acceso abierto.
Open text

Summary

Descripción general del contenido del recurso.

"Asynchrony due to reverse-triggering (RT) may appear in ARDS patients. The objective of this study is to validate an algo-rithm developed to detect these alterations in patient–ventilator interaction. We developed an algorithm that uses flow and airway pressure signals to classify breaths as normal, RT with or without breath stacking (BS) and patient initiated double-triggering (DT). The diagnostic performance of the algorithm was validated using two datasets of breaths, that are classified as stated above. The first dataset classification was based on visual inspection of esophageal pressure (Pes) signal from 699 breaths recorded from 11 ARDS patients. The other classification was obtained by vote of a group of 7 experts (2 physicians and 5 respiratory therapists, who were trained in ICU), who evaluated 1881 breaths gathered from recordings from 99 sub-jects. Experts used airway pressure and flow signals for breaths classification. The RT with or without BS represented 19% and 37% of breaths in Pes dataset while their frequency in the expert’s dataset were 3% and 12%, respectively. The DT was very infrequent in both datasets. Algorithm classification accuracy was 0.92 (95% CI 0.89–0.94, P < 0.001) and 0.96 (95% CI 0.95–0.97, P < 0.001), in comparison with Pes and experts’ opinion. Kappa statistics were 0.86 and 0.84, respectively. The algorithm precision, sensitivity and specificity for individual asynchronies were excellent. The algorithm yields an excellent accuracy for detecting clinically relevant asynchronies related to RT."

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

Rodríguez, P. O. E. A. (2020). Automatic detection of reverse‑triggering related asynchronies during mechanical ventilation in ARDS patients using flow and pressure signals. RI ITBA. http://ri.itba.edu.ar/handle/20.500.14769/1916

MLA

Rodríguez, Pablo Oscar et al. Automatic detection of reverse‑triggering related asynchronies during mechanical ventilation in ARDS patients using flow and pressure signals. RI ITBA, 2020. http://ri.itba.edu.ar/handle/20.500.14769/1916.

Chicago

Rodríguez, Pablo Oscar et al. 2020. Automatic detection of reverse‑triggering related asynchronies during mechanical ventilation in ARDS patients using flow and pressure signals. RI ITBA. http://ri.itba.edu.ar/handle/20.500.14769/1916.

Harvard

Rodríguez, P. O. E. A. 2020, Automatic detection of reverse‑triggering related asynchronies during mechanical ventilation in ARDS patients using flow and pressure signals, RI ITBA, available at: http://ri.itba.edu.ar/handle/20.500.14769/1916 [Accessed 8 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Automatic detection of reverse‑triggering related asynchronies during mechanical ventilation in ARDS patients using flow and pressure signals
Author / contributors
Rodríguez, Pablo Oscar et al
Publisher
RI ITBA
Publication year
2020
ISSN
1387-1307
ISSN
1387-1307
Language
English

Subjects

Explore related resources through these subjects.

Copied