Back to results
Bibliographic record · Consultation and access
Artículo

Evaluation of a continuous glucose monitoring system in neonatal foals

David Wong et al · Oxford University Press · 2021

Open access available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.
Serial publication

A de novo nonsense variant in the DMD gene associated with X‐linked dystrophin‐deficient muscular dystrophy in a cat

This serial publication contains 149 related contents.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Open access available

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Open resource

Summary

Descripción general del contenido del recurso.

Abstract Background Monitoring blood glucose concentrations is common in critically ill neonatal foals, especially septic foals and those receiving naso‐esophageal feedings or IV parenteral nutrition. Glucose typically is measured using a point‐of‐care (POC) glucometer but requires repeated restraint and blood collections, which may cause irritation at venipuncture sites and increased demands on nursing staff. Continuous glucose monitoring systems (CGMS) may provide an accurate alternative for monitoring blood glucose concentration. Objectives To determine the correlation and accuracy of a CGMS to monitor neonatal foals' blood glucose concentrations as compared to a POC glucometer and laboratory chemistry analysis (CHEM). Animals Samples from 4 healthy and 4 ill neonatal foals. Methods A CGMS was placed on each foal, and glucose measurements acquired from this device were compared to simultaneous measurements of blood glucose concentration using a POC glucometer and CHEM. Results Two‐hundred matched glucose measurements were collected from 8 neonatal foals. The mean bias (95% limits of agreement) between CGMS and CHEM, CGMS and POC glucometer, and POC glucometer and CHEM was 3.97 mg/dL (−32.5 to 40.4), 18.2 mg/dL (−28.8 to 65.2), and 22.18 mg/dL (−9.3 to 53.67), respectively. The Pearson's correlation coefficient (r) was significantly correlated among all devices: GCMS and CHEM (r = 0.81), CGMS and POC glucometer (r = 0.77) and POC glucometer‐CHEM (r = 0.92). Conclusions and Clinical Importance Within the blood glucose concentration ranges in this study (78‐212 mg/dL), CGMS measurements were significantly correlated with CHEM, suggesting that it is an acceptable method to provide meaningful, immediate, and continuous glucose concentration measurements in neonatal foals while eliminating the need for repeated restraint and blood collection.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, D. W. E. (2021). Evaluation of a continuous glucose monitoring system in neonatal foals. https://doi.org/10.1111/jvim.16186

MLA

al, David Wong et. "Evaluation of a continuous glucose monitoring system in neonatal foals." 2021. https://doi.org/10.1111/jvim.16186.

Chicago

al, David Wong et. 2021. "Evaluation of a continuous glucose monitoring system in neonatal foals.". https://doi.org/10.1111/jvim.16186.

Harvard

al, D. W. E. 2021, Evaluation of a continuous glucose monitoring system in neonatal foals, Oxford University Press, available at: https://doi.org/10.1111/jvim.16186 [Accessed 9 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Evaluation of a continuous glucose monitoring system in neonatal foals
Author / contributors
David Wong et al
Publisher
Oxford University Press
Publication year
2021
ISSN
0891-6640
ISSN
0891-6640
Language
English

Subjects

Explore related resources through these subjects.

Copied