Automated echocardiographic left ventricular dimension assessment in dogs using artificial intelligence: Development and validation

Catherine C. Stowell et al · Oxford University Press · 2024

Supplementary material available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.
Serial publication

A de novo nonsense variant in the DMD gene associated with X‐linked dystrophin‐deficient muscular dystrophy in a cat

This serial publication contains 149 related contents.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Supplementary material available

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Open material

Summary

Descripción general del contenido del recurso.

Abstract Background Artificial intelligence (AI) could improve accuracy and reproducibility of echocardiographic measurements in dogs. Hypothesis A neural network can be trained to measure echocardiographic left ventricular (LV) linear dimensions in dogs. Animals Training dataset: 1398 frames from 461 canine echocardiograms from a single specialist center. Validation: 50 additional echocardiograms from the same center. Methods Training dataset: a right parasternal 4‐chamber long axis frame from each study, labeled by 1 of 18 echocardiographers, marking anterior and posterior points of the septum and free wall. Validation Dataset End‐diastolic and end‐systolic frames from 50 studies, annotated twice (blindly) by 13 experts, producing 26 measurements of each site from each frame. The neural network also made these measurements. We quantified its accuracy as the deviation from the expert consensus, using the individual‐expert deviation from consensus as context for acceptable variation. The deviation of the AI measurement away from the expert consensus was assessed on each individual frame and compared with the root‐mean‐square‐variation of the individual expert opinions away from that consensus. Results For the septum in end‐diastole, individual expert opinions deviated by 0.12 cm from the consensus, while the AI deviated by 0.11 cm (P = .61). For LVD, the corresponding values were 0.20 cm for experts and 0.13 cm for AI (P = .65); for the free wall, experts 0.20 cm, AI 0.13 cm (P < .01). In end‐systole, there were no differences between individual expert and AI performances. Conclusions and Clinical Importance An artificial intelligence network can be trained to adequately measure linear LV dimensions, with performance indistinguishable from that of experts.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, C. C. S. E. (2024). Automated echocardiographic left ventricular dimension assessment in dogs using artificial intelligence: Development and validation. https://doi.org/10.1111/jvim.17012

MLA

al, Catherine C. Stowell et. "Automated echocardiographic left ventricular dimension assessment in dogs using artificial intelligence: Development and validation." 2024. https://doi.org/10.1111/jvim.17012.

Chicago

al, Catherine C. Stowell et. 2024. "Automated echocardiographic left ventricular dimension assessment in dogs using artificial intelligence: Development and validation.". https://doi.org/10.1111/jvim.17012.

Harvard

al, C. C. S. E. 2024, Automated echocardiographic left ventricular dimension assessment in dogs using artificial intelligence: Development and validation, Oxford University Press, available at: https://doi.org/10.1111/jvim.17012 [Accessed 7 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Automated echocardiographic left ventricular dimension assessment in dogs using artificial intelligence: Development and validation
Author / contributors
Catherine C. Stowell et al
Publisher
Oxford University Press
Publication year
2024
ISSN
0891-6640
ISSN
0891-6640
Language
English

Subjects

Explore related resources through these subjects.

Copied