Back to results
Bibliographic record · Consultation and access
Artículo

Accuracy of a magnetic resonance imaging‐based 3D printed stereotactic brain biopsy device in dogs

Sarah Gutmann et al · Oxford University Press · 2020

Open access available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.
Serial publication

A de novo nonsense variant in the DMD gene associated with X‐linked dystrophin‐deficient muscular dystrophy in a cat

This serial publication contains 149 related contents.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Open access available

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Open resource

Summary

Descripción general del contenido del recurso.

Abstract Background Brain biopsy of intracranial lesions is often necessary to determine specific therapy. The cost of the currently used stereotactic rigid frame and optical tracking systems for brain biopsy in dogs is often prohibitive or accuracy is not sufficient for all types of lesion. Objectives To evaluate the application accuracy of an inexpensive magnetic resonance imaging‐based personalized, 3D printed brain biopsy device. Animals Twenty‐two dog heads from cadavers were separated into 2 groups according to body weight (<15 kg, >20 kg). Methods Experimental study. Two target points in each cadaver head were used (target point 1: caudate nucleus, target point 2: piriform lobe). Comparison between groups was performed using the independent Student's t test or the nonparametric Mann‐Whitney U Test. Results The total median target point deviation was 0.83 mm (range 0.09‐2.76 mm). The separate median target point deviations for target points 1 and 2 in all dogs were 0.57 mm (range: 0.09‐1.25 mm) and 0.85 mm (range: 0.14‐2.76 mm), respectively. Conclusion and Clinical Importance This magnetic resonance imaging‐based 3D printed stereotactic brain biopsy device achieved an application accuracy that was better than the accuracy of most brain biopsy systems that are currently used in veterinary medicine. The device can be applied to every size and shape of skull and allows precise positioning of brain biopsy needles in dogs.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, S. G. E. (2020). Accuracy of a magnetic resonance imaging‐based 3D printed stereotactic brain biopsy device in dogs. https://doi.org/10.1111/jvim.15739

MLA

al, Sarah Gutmann et. "Accuracy of a magnetic resonance imaging‐based 3D printed stereotactic brain biopsy device in dogs." 2020. https://doi.org/10.1111/jvim.15739.

Chicago

al, Sarah Gutmann et. 2020. "Accuracy of a magnetic resonance imaging‐based 3D printed stereotactic brain biopsy device in dogs.". https://doi.org/10.1111/jvim.15739.

Harvard

al, S. G. E. 2020, Accuracy of a magnetic resonance imaging‐based 3D printed stereotactic brain biopsy device in dogs, Oxford University Press, available at: https://doi.org/10.1111/jvim.15739 [Accessed 9 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Accuracy of a magnetic resonance imaging‐based 3D printed stereotactic brain biopsy device in dogs
Author / contributors
Sarah Gutmann et al
Publisher
Oxford University Press
Publication year
2020
ISSN
0891-6640
ISSN
0891-6640
Language
English

Subjects

Explore related resources through these subjects.

Copied