Back to results
Bibliographic record · Consultation and access
Artículo

N4ITK: Improved N3 Bias Correction

Nicholas J. Tustison; Brian Avants; Philip A. Cook; Yuanjie Zheng; Alexander Egan; Paul A. Yushkevich; James C. Gee · IEEE Transactions on Medical Imaging · 2010

Resource page
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.

Resource access

Open the content from the main option or choose another available source.

OpenAlex OpenAlex Works
Entrar por OpenAlex
Main access

Resource page

Resource reference page. Full text availability has not been automatically confirmed.
Open resource

Summary

Descripción general del contenido del recurso.

A variant of the popular nonparametric nonuniform intensity normalization (N3) algorithm is proposed for bias field correction. Given the superb performance of N3 and its public availability, it has been the subject of several evaluation studies. These studies have demonstrated the importance of certain parameters associated with the B-spline least-squares fitting. We propose the substitution of a recently developed fast and robust B-spline approximation routine and a modified hierarchical optimization scheme for improved bias field correction over the original N3 algorithm. Similar to the N3 algorithm, we also make the source code, testing, and technical documentation of our contribution, which we denote as "N4ITK," available to the public through the Insight Toolkit of the National Institutes of Health. Performance assessment is demonstrated using simulated data from the publicly available Brainweb database, hyperpolarized (3)He lung image data, and 9.4T postmortem hippocampus data.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

Tustison, N. J, Avants, B, Cook, P. A, Zheng, Y, Egan, A, Yushkevich, P. A, & Gee, J. C. (2010). N4ITK: Improved N3 Bias Correction. https://doi.org/10.1109/tmi.2010.2046908

MLA

Tustison, Nicholas J, et al. "N4ITK: Improved N3 Bias Correction." 2010. https://doi.org/10.1109/tmi.2010.2046908.

Chicago

Tustison, Nicholas J, Brian Avants, Philip A. Cook, Yuanjie Zheng, Alexander Egan, Paul A. Yushkevich, and James C. Gee. 2010. "N4ITK: Improved N3 Bias Correction.". https://doi.org/10.1109/tmi.2010.2046908.

Harvard

Tustison, N. J. et al. 2010, N4ITK: Improved N3 Bias Correction, IEEE Transactions on Medical Imaging, available at: https://doi.org/10.1109/tmi.2010.2046908 [Accessed 8 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
N4ITK: Improved N3 Bias Correction
Author / contributors
Nicholas J. Tustison; Brian Avants; Philip A. Cook; Yuanjie Zheng; Alexander Egan; Paul A. Yushkevich; James C. Gee
Publisher
IEEE Transactions on Medical Imaging
Publication year
2010
Language
English

Subjects

Explore related resources through these subjects.

Copied