Back to results
Bibliographic record · Consultation and access
Artículo

Pencil-beam scanning catheter for intracoronary optical coherence tomography

Jiqiang Kang et al · Editorial Office of Opto-Electronic Journals Group, Institute of Optics and Electronics, CAS, China · 2022

Supplementary material available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Supplementary material available

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Open material

Summary

Descripción general del contenido del recurso.

Current gradient-index (GRIN) lens based proximal-driven intracoronary optical coherence tomography (ICOCT) probes consist of a spacer and a GRIN lens with large gradient constant. This design provides great flexibility to control beam profiles, but the spacer length should be well controlled to obtain desired beam profiles and thus it sets an obstacle in mass catheter fabrication. Besides, although GRIN lens with large gradient constant can provide tight focus spot, it has short depth of focus and fast-expanded beam which leads to poor lateral resolution for deep tissue. In this paper, a type of spacer-removed probe is demonstrated with a small gradient constant GRIN lens. This design simplifies the fabrication process and is suitable for mass production. The output beam of the catheter is a narrow nearly collimated light beam, referred to as pencil beam here. The full width at half maximum beam size varies from 35.1 µm to 75.3 µm in air over 3-mm range. Probe design principles are elaborated with probe/catheter fabrication and performance test. The in vivo imaging of the catheter was verified by a clinical ICOCT system. Those results prove that this novel pencil-beam scanning catheter is potentially a good choice for ICOCT systems.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, J. K. E. (2022). Pencil-beam scanning catheter for intracoronary optical coherence tomography. https://doi.org/10.29026/oea.2022.200050

MLA

al, Jiqiang Kang et. "Pencil-beam scanning catheter for intracoronary optical coherence tomography." 2022. https://doi.org/10.29026/oea.2022.200050.

Chicago

al, Jiqiang Kang et. 2022. "Pencil-beam scanning catheter for intracoronary optical coherence tomography.". https://doi.org/10.29026/oea.2022.200050.

Harvard

al, J. K. E. 2022, Pencil-beam scanning catheter for intracoronary optical coherence tomography, Editorial Office of Opto-Electronic Journals Group, Institute of Optics and Electronics, CAS, China, available at: https://doi.org/10.29026/oea.2022.200050 [Accessed 7 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Pencil-beam scanning catheter for intracoronary optical coherence tomography
Author / contributors
Jiqiang Kang et al
Publisher
Editorial Office of Opto-Electronic Journals Group, Institute of Optics and Electronics, CAS, China
Publication year
2022
ISSN
2096-4579
ISSN
2096-4579
Language
English

Subjects

Explore related resources through these subjects.

Copied