Back to results
Bibliographic record · Consultation and access
Artículo

Tooth Position and Deformation of Flexspline Assembled with Cam in Harmonic Drive Based on Force Analysis

Yunpeng Yao et al · KeAi Communications Co., Ltd · 2021

Open access available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Open access available

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Open resource

Summary

Descripción general del contenido del recurso.

Abstract Deformation of the flexspline is the basis of analyzing tooth trajectory and designing tooth profile. Considering the tooth influence on the position of equivalent neutral layer, a piecewise method for calculating the deformation of flexspline assembled with a cam wave generator is presented in this paper. Firstly, a mechanic model of a ring of uniform thickness in contact with a rigid cam is established. The displacements of the ring inside and outside an unknown wrapping angle are determined by the geometric constraints of the cam profile and the equilibrium relationship, respectively. Meanwhile, the wrapping angle is solved according to the boundary conditions. The assembly forces are derived to investigate the circumferential elongation and strain. Then, considering the tooth effects on the neutral layer of flexspline, the tooth is positioned on the equivalent neutral layer, which is the non-elongation layer within one gear pitch but offset from the geometric mid-layer. The equivalent neutral layer is positioned by the empirical formula of the offset ratio, which is summarized by the orthogonal simulation on finite element models of racks. Finally, finite element models of a ring-shaped and a cup-shaped flexspline assembled with elliptical cam are established to verify the effectiveness and accuracy of the piecewise method. The results show that, compared with the geometric method, the tooth positioning deviation calculated by the piecewise method can be reduced by about 70% with a more accurate deformation description from the geometric condition and mechanic condition inside and outside the wrapping angle.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, Y. Y. E. (2021). Tooth Position and Deformation of Flexspline Assembled with Cam in Harmonic Drive Based on Force Analysis. https://doi.org/10.1186/s10033-021-00621-z

MLA

al, Yunpeng Yao et. "Tooth Position and Deformation of Flexspline Assembled with Cam in Harmonic Drive Based on Force Analysis." 2021. https://doi.org/10.1186/s10033-021-00621-z.

Chicago

al, Yunpeng Yao et. 2021. "Tooth Position and Deformation of Flexspline Assembled with Cam in Harmonic Drive Based on Force Analysis.". https://doi.org/10.1186/s10033-021-00621-z.

Harvard

al, Y. Y. E. 2021, Tooth Position and Deformation of Flexspline Assembled with Cam in Harmonic Drive Based on Force Analysis, KeAi Communications Co, Ltd, available at: https://doi.org/10.1186/s10033-021-00621-z [Accessed 9 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Tooth Position and Deformation of Flexspline Assembled with Cam in Harmonic Drive Based on Force Analysis
Author / contributors
Yunpeng Yao et al
Publisher
KeAi Communications Co., Ltd
Publication year
2021
ISSN
1000-9345
ISSN
1000-9345
Language
English

Subjects

Explore related resources through these subjects.

Copied