Back to results
Bibliographic record · Consultation and access
Artículo

Evaluation of a Chemiluminescent Immunoassay for Measurement of Equine Insulin

H.B. Carslake et al · Oxford University Press · 2017

Supplementary material available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.
Serial publication

A de novo nonsense variant in the DMD gene associated with X‐linked dystrophin‐deficient muscular dystrophy in a cat

This serial publication contains 149 related contents.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Supplementary material available

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Open material

Summary

Descripción general del contenido del recurso.

Background Many diagnostic tests for insulin dysregulation use reference intervals established with an insulin radioimmunoassay (RIA) that is no longer available. A chemiluminescent immunoassay (CLIA) is commonly used for the measurement of serum insulin concentration in clinical practice but requires further validation, especially at clinically relevant reference intervals. Objectives To evaluate the CLIA for measurement of equine insulin and compare it to the previously validated, but now unavailable RIA. Samples Equine serum samples (n = 78) from clinical and experimental studies. Methods In this experimental study, performance of the CLIA was evaluated using standard variables, including comparison with the RIA. Continuous and binary outcomes were analyzed. Results The CLIA showed good intra‐assay (coefficient of variation [CV], 1.8–2.4%) and interassay (CV, 3–7.1%) precision. Acceptable recovery on dilution (100 ± 10%) was achieved only at dilutions <1:1. Recovery on addition was acceptable. Comparison of the CLIA and RIA showed strong positive correlation (r = 0.91–0.98), with fixed and proportional bias. At 3 diagnostic cutoffs, sensitivity of CLIA compared with RIA ranged from 67 to 100% and specificity from 96 to 100%. Conclusions and Clinical Importance The CLIA is a highly repeatable assay which is suitable for within‐ and between‐horse comparisons. Dilution of high concentration samples should be performed with charcoal‐stripped serum (CSS) and at the lowest dilution factor possible. At concentrations commonly used for diagnosis of insulin dysregulation (≤100 μIU/mL), results from the CLIA tend to be lower than from the RIA and should be interpreted accordingly. Further standardization of equine insulin assays is required.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, H. C. E. (2017). Evaluation of a Chemiluminescent Immunoassay for Measurement of Equine Insulin. https://doi.org/10.1111/jvim.14657

MLA

al, H.B. Carslake et. "Evaluation of a Chemiluminescent Immunoassay for Measurement of Equine Insulin." 2017. https://doi.org/10.1111/jvim.14657.

Chicago

al, H.B. Carslake et. 2017. "Evaluation of a Chemiluminescent Immunoassay for Measurement of Equine Insulin.". https://doi.org/10.1111/jvim.14657.

Harvard

al, H. C. E. 2017, Evaluation of a Chemiluminescent Immunoassay for Measurement of Equine Insulin, Oxford University Press, available at: https://doi.org/10.1111/jvim.14657 [Accessed 5 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Evaluation of a Chemiluminescent Immunoassay for Measurement of Equine Insulin
Author / contributors
H.B. Carslake et al
Publisher
Oxford University Press
Publication year
2017
ISSN
0891-6640
ISSN
0891-6640
Language
English

Subjects

Explore related resources through these subjects.

Copied