Back to results
Bibliographic record · Consultation and access
Artículo

Experimental acrylonitrile butadiene styrene and polyamide evisceration implant: a rabbit clinical and histopathology study

D.C. Gomes Júnior et al · Universidade Federal de Minas Gerais, Escola de Veterinária

Open access available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.
Serial publication

Ação do estanozolol sobre a histologia renal e hepática em ratos treinados com natação

This serial publication contains 254 related contents.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Open access available

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Open resource

Summary

Descripción general del contenido del recurso.

ABSTRACT The purpose of this study was to evaluate acrylonitrile butadiene styrene (ABS) and polyamide implants in rabbits submitted to evisceration at the macroscopic and microstructure level and to assess clinical response and histopathological changes as well. For the experimental study implants of 12mm diameter were prepared by rapid prototyping, weighed and the outer and inner surfaces evaluated macroscopically and by electron microscopy. In addition, a compression test was performed and ultrastructural damage was then determined. After evisceration of the left eyeball, nine New Zealand rabbits received ABS implants and nine others received polyamide implants. The animals were assessed daily for 15 days after surgery and every seven days until the end of the study (90 days). Histopathological evaluation was performed at 15, 45 and 90 days after surgery. The ABS implants weighed approximately 0.44g, while the polyamide ones weighed 0.61g. Scanning electron microscopy demonstrated that the ABS implants had regular-sized, equidistant micropores, while the polyamide ones showed micropores of various sizes. The force required to fracture the ABS implant was 14.39 ±0.60 Mpa, while for the polyamide one, it was 16.80 ±1.05 Mpa. Fifteen days after surgery, we observed centripetal tissue infiltration and scarce inflammatory infiltrate. Implants may be used in the filling of anophthalmic cavities, because they are inert, biocompatible and allow tissue integration.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, D. G. J. E. (s. f.). Experimental acrylonitrile butadiene styrene and polyamide evisceration implant: a rabbit clinical and histopathology study. https://doi.org/10.1590/1678-4162-8680

MLA

al, D.C. Gomes Júnior et. "Experimental acrylonitrile butadiene styrene and polyamide evisceration implant: a rabbit clinical and histopathology study.". https://doi.org/10.1590/1678-4162-8680.

Chicago

al, D.C. Gomes Júnior et. s. f. "Experimental acrylonitrile butadiene styrene and polyamide evisceration implant: a rabbit clinical and histopathology study.". https://doi.org/10.1590/1678-4162-8680.

Harvard

al, D. G. J. E. s. f, Experimental acrylonitrile butadiene styrene and polyamide evisceration implant: a rabbit clinical and histopathology study, Universidade Federal de Minas Gerais, Escola de Veterinária, available at: https://doi.org/10.1590/1678-4162-8680 [Accessed 8 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Experimental acrylonitrile butadiene styrene and polyamide evisceration implant: a rabbit clinical and histopathology study
Author / contributors
D.C. Gomes Júnior et al
Publisher
Universidade Federal de Minas Gerais, Escola de Veterinária
ISSN
1678-4162
ISSN
1678-4162
Language
English

Subjects

Explore related resources through these subjects.

Copied