Back to results
Bibliographic record · Consultation and access
Artículo

Optimal Head Rotation for Ultrasound- Guided Internal Jugular Vein Cannulation in Obese Patients: A Prospective Observational Study

Manish Kotwani et al · Sri Devaraj Urs Academy of Higher Education and Research · 2026

Open access available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Open access available

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Open resource

Summary

Descripción general del contenido del recurso.

Background: Ultrasound-guided internal jugular vein (IJV) cannulation is standard practice, but the risk of accidental common carotid artery (CCA) puncture persists, especially in obese patients. Head rotation manoeuvres aim to improve IJV accessibility but may increase IJV-CCA overlap. The optimal degree of head rotation to minimise this overlap although studied in normal patients remains largely underexplored in obese patients. Aims: To determine the head rotation angle (15°–60°) that maximizes IJV diameter while minimizing IJV-CCA overlap in obese patients (BMI ≥25 kg/m²). Material and Methods: Sixty obese patients were stratified by BMI (Group 1: 25–29.9; Group 2: 30–39.9; Group 3: ≥40) in the pre-operative room. In supine position with 15° Trendelenburg tilt, right IJV and CCA were imaged using 5–12 MHz linear probe at cricoid level. Transverse and anteroposterior diameters of the right sided IJV and CCA and their overlap were measured using real time ultrasound at 15°, 30°, 45° and 60° of head rotations. Results: IJV-CCA overlap increased significantly with rotation: 34.9% (with15°) to 55.3% (with 60°) (P<0.001). Overlap was highest in Group 3 (BMI ≥40). No significant change in IJV diameter was observed. The safest rotation was ≤45° for BMI 30–39.9 and ≤60° for BMI 25–29.9. Conclusion: Head rotation >45° in obese patients significantly increases CCA puncture risk. Ultrasound-guided cannulation at ≤45° is recommended for BMI ≥30 kg/m². Keywords: Internal jugular vein, Obesity, Ultrasound guidance, Head rotation, Common carotid artery

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, M. K. E. (2026). Optimal Head Rotation for Ultrasound- Guided Internal Jugular Vein Cannulation in Obese Patients: A Prospective Observational Study. https://doi.org/10.58739/jcbs/v16i1.25.247

MLA

al, Manish Kotwani et. "Optimal Head Rotation for Ultrasound- Guided Internal Jugular Vein Cannulation in Obese Patients: A Prospective Observational Study." 2026. https://doi.org/10.58739/jcbs/v16i1.25.247.

Chicago

al, Manish Kotwani et. 2026. "Optimal Head Rotation for Ultrasound- Guided Internal Jugular Vein Cannulation in Obese Patients: A Prospective Observational Study.". https://doi.org/10.58739/jcbs/v16i1.25.247.

Harvard

al, M. K. E. 2026, Optimal Head Rotation for Ultrasound- Guided Internal Jugular Vein Cannulation in Obese Patients: A Prospective Observational Study, Sri Devaraj Urs Academy of Higher Education and Research, available at: https://doi.org/10.58739/jcbs/v16i1.25.247 [Accessed 10 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Optimal Head Rotation for Ultrasound- Guided Internal Jugular Vein Cannulation in Obese Patients: A Prospective Observational Study
Author / contributors
Manish Kotwani et al
Publisher
Sri Devaraj Urs Academy of Higher Education and Research
Publication year
2026
ISSN
2231-4180
ISSN
2231-4180
Language
English
Copied