Back to results
Bibliographic record · Consultation and access
Artículo

Electromagnetic field detectors based on spintronics devices

R.L. Politanskyi et al · Vasyl Stefanyk Carpathian National University · 2023

Open-access full text
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Open-access full text

Texto completo identificado como acceso abierto.
Open text

Summary

Descripción general del contenido del recurso.

The paper proposes a model of an electromagnetic radiation sensor that uses the precession of the magnetization vector in a ferromagnet (ferromagnetic resonance) as a result of absorbing the energy of an incident electromagnetic wave, the generation of a spin current as a result of this precession, the generation of a spin-polarized current as a result of the passage of a spin current in a non-magnetic metal, and a change in the direction of magnetization of a ferromagnetic layer with a low coercive force (free layer) due to the passage of a spin-polarized current. Then the radiation will be detected by its effect on the electrical resistance of the entire structure, which depends on the mutual directions (parallel or antiparallel) of magnetization of the free and fixed (with a large coercive force) ferromagnetic layers (phenomenon of giant magnetic resistance). The dependence of the spin-polarized current in the device on the frequency and amplitude of the incident electromagnetic wave with linear polarization was calculated. A method of calculating the range of amplitude and frequency values of radiation that can be detected by the sensor has been developed. The parameters of this model are the detection time and the number of spin gates in one sensor. Calculations are given for a ferromagnetic layer made of permalloy and for spin valves with four different critical current values that determine the process of remagnetization of the free layer: 20, 50, 100, and 200 microamps.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, R. P. E. (2023). Electromagnetic field detectors based on spintronics devices. https://doi.org/10.15330/pcss.24.3.433-440

MLA

al, R.L. Politanskyi et. "Electromagnetic field detectors based on spintronics devices." 2023. https://doi.org/10.15330/pcss.24.3.433-440.

Chicago

al, R.L. Politanskyi et. 2023. "Electromagnetic field detectors based on spintronics devices.". https://doi.org/10.15330/pcss.24.3.433-440.

Harvard

al, R. P. E. 2023, Electromagnetic field detectors based on spintronics devices, Vasyl Stefanyk Carpathian National University, available at: https://doi.org/10.15330/pcss.24.3.433-440 [Accessed 8 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Electromagnetic field detectors based on spintronics devices
Author / contributors
R.L. Politanskyi et al
Publisher
Vasyl Stefanyk Carpathian National University
Publication year
2023
ISSN
1729-4428
ISSN
1729-4428
Language
English

Subjects

Explore related resources through these subjects.

Copied