Back to results
Bibliographic record · Consultation and access
Artículo

Validation of a flash glucose monitoring system in outpatient diabetic cats

Emily K. Shea et al · Oxford University Press · 2021

Open access available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.
Serial publication

A de novo nonsense variant in the DMD gene associated with X‐linked dystrophin‐deficient muscular dystrophy in a cat

This serial publication contains 149 related contents.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Open access available

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Open resource

Summary

Descripción general del contenido del recurso.

Abstract Background Interstitial glucose (IG) concentration measurement using a flash glucose monitoring system (FGMS) is a noninvasive, affordable, and informative method to regulate patients with diabetes mellitus (DM) but has not been fully validated in outpatient cats with DM. Objectives To further validate the FreeStyle Libre FGMS in outpatient diabetic cats. Animals Eight client‐owned cats with DM. Methods Prospective observational validation study. Tissue glue was used to attach the sensor to the cat. Lin's concordance correlation coefficient (ρc) was used to compare IG concentrations measured by the FGMS to blood glucose concentrations measured using an automated biochemistry analyzer (ABA) and point‐of‐care glucometer (POCG). Results Data from 15 sensor placements in 8 cats were analyzed. Paired IG and ABA glucose concentrations (139 samples) had excellent correlation (ρc = 0.96) as did IG and POCG glucose concentrations (142 samples, ρc = 0.92). Sensor failure or displacement were recorded for 12/15 (80%) sensor placements. Median time of sensor activity was 7 days (range, 2‐13 days). Conclusions and Clinical Importance In outpatient cats with DM, the FGMS‐measured IG concentration correlated well with ABA‐measured blood glucose concentration, but a high rate of sensor failures was observed.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, E. K. S. E. (2021). Validation of a flash glucose monitoring system in outpatient diabetic cats. https://doi.org/10.1111/jvim.16216

MLA

al, Emily K. Shea et. "Validation of a flash glucose monitoring system in outpatient diabetic cats." 2021. https://doi.org/10.1111/jvim.16216.

Chicago

al, Emily K. Shea et. 2021. "Validation of a flash glucose monitoring system in outpatient diabetic cats.". https://doi.org/10.1111/jvim.16216.

Harvard

al, E. K. S. E. 2021, Validation of a flash glucose monitoring system in outpatient diabetic cats, Oxford University Press, available at: https://doi.org/10.1111/jvim.16216 [Accessed 8 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Validation of a flash glucose monitoring system in outpatient diabetic cats
Author / contributors
Emily K. Shea et al
Publisher
Oxford University Press
Publication year
2021
ISSN
0891-6640
ISSN
0891-6640
Language
English

Subjects

Explore related resources through these subjects.

Copied