Back to results
Bibliographic record · Consultation and access
Artículo

Accuracy of a flash glucose monitoring system in dogs with diabetic ketoacidosis

Eleonora Malerba et al · Oxford University Press · 2020

Supplementary material available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.
Serial publication

A de novo nonsense variant in the DMD gene associated with X‐linked dystrophin‐deficient muscular dystrophy in a cat

This serial publication contains 149 related contents.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Supplementary material available

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Open material

Summary

Descripción general del contenido del recurso.

Abstract Background A factory‐calibrated flash glucose monitoring system (FGMS; FreeStyle Libre) recently was evaluated in dogs with uncomplicated diabetes mellitus. It is not known if this system is reliable during diabetic ketoacidosis (DKA). Objectives To assess the performance of the FGMS in dogs with DKA and to determine the effect of severity of ketosis and acidosis, lactate concentration, body condition score (BCS), and time wearing the sensor on the accuracy of the device. Animals Fourteen client‐owned dogs with DKA. Methods The interstitial glucose (IG) measurements were compared with blood glucose (BG) measurements obtained using a validated portable glucometer. The influence of changes in metabolic variables (β‐hydroxybutyrate, pH, bicarbonate, and lactate) and the effect of BCS and time wearing on sensor performance were evaluated. Accuracy was determined by fulfillment of ISO15197:2013 criteria. Results Metabolic variables, BCS, and time wearing were not associated with the accuracy of the sensor. Good agreement between IG measurements and BG was obtained both before and after DKA resolution (r = .88 and r = .93, respectively). Analytical accuracy was not achieved, whereas clinical accuracy was demonstrated with 100% and 99.6% of results in zones A + B of the Parkes consensus error grid analysis before and after DKA resolution, respectively. Conclusions and Clinical Importance Changes in metabolic variables, BCS, and time wearing do not seem to affect agreement between IG and BG. Despite not fulfilling the ISO requirements, the FGMS provides clinically accurate estimates of BG in dogs with DKA.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, E. M. E. (2020). Accuracy of a flash glucose monitoring system in dogs with diabetic ketoacidosis. https://doi.org/10.1111/jvim.15657

MLA

al, Eleonora Malerba et. "Accuracy of a flash glucose monitoring system in dogs with diabetic ketoacidosis." 2020. https://doi.org/10.1111/jvim.15657.

Chicago

al, Eleonora Malerba et. 2020. "Accuracy of a flash glucose monitoring system in dogs with diabetic ketoacidosis.". https://doi.org/10.1111/jvim.15657.

Harvard

al, E. M. E. 2020, Accuracy of a flash glucose monitoring system in dogs with diabetic ketoacidosis, Oxford University Press, available at: https://doi.org/10.1111/jvim.15657 [Accessed 5 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Accuracy of a flash glucose monitoring system in dogs with diabetic ketoacidosis
Author / contributors
Eleonora Malerba et al
Publisher
Oxford University Press
Publication year
2020
ISSN
0891-6640
ISSN
0891-6640
Language
English

Subjects

Explore related resources through these subjects.

Copied