Back to results
Bibliographic record · Consultation and access
Artículo

Accuracy of the Freestyle Libre 3 Continuous Glucose Monitoring System in Hypo‐ and Euglycemic Cats

Antonio M. Tardo et al · Oxford University Press · 2025

Supplementary material available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.
Serial publication

A de novo nonsense variant in the DMD gene associated with X‐linked dystrophin‐deficient muscular dystrophy in a cat

This serial publication contains 149 related contents.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Supplementary material available

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Open material

Summary

Descripción general del contenido del recurso.

ABSTRACT Background The FreeStyle Libre 3 (FSL3) has several improvements compared to previous FreeStyle Libre systems, but its accuracy has not yet been determined in cats. In diabetic people, FSL3 offers increased accuracy, and its smaller size could be advantageous for use in veterinary patients. Objectives Assess the accuracy of FSL3 in cats with experimentally induced hypoglycemia. Animals Seven healthy, purpose‐bred cats. Methods Hyperinsulinemic‐hypoglycemic clamps were performed. Interstitial glucose concentration (IG), measured by FSL3, was compared to blood glucose concentration (BG) measured by AlphaTrak2. Data were analyzed for all paired measurements (n = 474) and during stable BG (≤ 1 mg/dL/min change over 10 min). Pearson's r test, Bland–Altman test, and Parkes Error Grid analysis (EGA) respectively used to determine correlation, bias, and clinical accuracy. Results Blood glucose concentration and IG correlated strongly (r = 0.86, p < 0.0001) in stable glycemia and moderately at all rates of change (r = 0.73, p < 0.0001). Analytical accuracy was not achieved, whereas clinical accuracy was demonstrated with 99%–100% of the results in zones A + B of the Parkes EGA. Interstitial glucose concentration underestimated BG in euglycemia and mild hypoglycemia (mean −11.7 ± 11.2, −5.5 ± 9.1, −1.5 ± 6.0 mg/dL in the ranges 91–120, 66–90, and 56–65 mg/dL, respectively), but overestimated BG in marked hypoglycemia (mean 6.3 ± 5.7, 15.7 ± 5.6 mg/dL in the ranges 46–55 and < 45 mg/dL, respectively). Conclusions The FSL3 underestimates BG across most of the hypo‐euglycemic range but overestimates BG in marked hypoglycemia (< 55 mg/dL). Recognizing the proportional, glycemic‐dependent bias of FSL3 improves the safety of its clinical application in cats.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, A. M. T. E. (2025). Accuracy of the Freestyle Libre 3 Continuous Glucose Monitoring System in Hypo‐ and Euglycemic Cats. https://doi.org/10.1111/jvim.70048

MLA

al, Antonio M. Tardo et. "Accuracy of the Freestyle Libre 3 Continuous Glucose Monitoring System in Hypo‐ and Euglycemic Cats." 2025. https://doi.org/10.1111/jvim.70048.

Chicago

al, Antonio M. Tardo et. 2025. "Accuracy of the Freestyle Libre 3 Continuous Glucose Monitoring System in Hypo‐ and Euglycemic Cats.". https://doi.org/10.1111/jvim.70048.

Harvard

al, A. M. T. E. 2025, Accuracy of the Freestyle Libre 3 Continuous Glucose Monitoring System in Hypo‐ and Euglycemic Cats, Oxford University Press, available at: https://doi.org/10.1111/jvim.70048 [Accessed 5 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Accuracy of the Freestyle Libre 3 Continuous Glucose Monitoring System in Hypo‐ and Euglycemic Cats
Author / contributors
Antonio M. Tardo et al
Publisher
Oxford University Press
Publication year
2025
ISSN
0891-6640
ISSN
0891-6640
Language
English

Subjects

Explore related resources through these subjects.

Copied