Back to results
Bibliographic record · Consultation and access
Artículo

Comparison between Vernier-cascade and MZI as transducer for biosensing with on-chip spectral filter

Martens Daan et al · Wiley · 2017

Supplementary material available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Supplementary material available

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Open material

Summary

Descripción general del contenido del recurso.

The Mach-Zehnder interferometer (MZI) and the Vernier-cascade are highly responsive photonic sensors with large design freedom. They are therefore very suitable for interrogation through a broadband source and an on-chip spectral filter, a sensing scheme that is well equipped for point-of-care applications. In this work, the MZI is shown to outperform the Vernier-cascade through a better minimum detectable wavelength shift as well as a higher power efficiency, indicating its superiority in this sensing scheme. Fabricated MZIs yield bulk detection limits down to 8.8×10−7 refractive index units (RIU) in a point-of-care compatible measuring setup, indicating the potential of the proposed sensing scheme.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, M. D. E. (2017). Comparison between Vernier-cascade and MZI as transducer for biosensing with on-chip spectral filter. https://doi.org/10.1515/nanoph-2016-0181

MLA

al, Martens Daan et. "Comparison between Vernier-cascade and MZI as transducer for biosensing with on-chip spectral filter." 2017. https://doi.org/10.1515/nanoph-2016-0181.

Chicago

al, Martens Daan et. 2017. "Comparison between Vernier-cascade and MZI as transducer for biosensing with on-chip spectral filter.". https://doi.org/10.1515/nanoph-2016-0181.

Harvard

al, M. D. E. 2017, Comparison between Vernier-cascade and MZI as transducer for biosensing with on-chip spectral filter, Wiley, available at: https://doi.org/10.1515/nanoph-2016-0181 [Accessed 6 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Comparison between Vernier-cascade and MZI as transducer for biosensing with on-chip spectral filter
Author / contributors
Martens Daan et al
Publisher
Wiley
Publication year
2017
ISSN
2192-8606
ISSN
2192-8606
Language
English

Subjects

Explore related resources through these subjects.

Copied