Back to results
Bibliographic record · Consultation and access
Artículo

Successful application of closed loop stimulation pacemakers with remote monitoring in 3 miniature donkeys with syncope

Lisa De Lange et al · Oxford University Press · 2021

Supplementary material available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.
Serial publication

A de novo nonsense variant in the DMD gene associated with X‐linked dystrophin‐deficient muscular dystrophy in a cat

This serial publication contains 149 related contents.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Supplementary material available

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Open material

Summary

Descripción general del contenido del recurso.

Abstract Rate‐adaptive single chamber pacemakers with accelerometer, closed loop stimulation (CLS), and remote monitoring functionality (Eluna 8 SR‐T, Biotronik, SE & Co, Germany) were implanted in 3 miniature donkeys with third‐degree atrioventricular block and syncope. After recovery, different pacemaker programming modes were tested at rest, during stress without physical exercise and during physical exercise. Pacing rates were compared to actual atrial rates and showed that CLS functionality allowed physiological heart rate adaptation. A transmitter installed in the stable provided wireless connection of the pacemaker to the internet. Home monitoring was activated which performed daily wireless transmission of pacemaker functional measurements to an online server allowing diagnosis of pathological arrhythmias and pacemaker malfunction from a distance. Closed loop stimulation and remote monitoring functionality resulted in nearly physiological rate adaptation and allowed remote “from‐the‐stable” patient follow‐up.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, L. D. L. E. (2021). Successful application of closed loop stimulation pacemakers with remote monitoring in 3 miniature donkeys with syncope. https://doi.org/10.1111/jvim.16305

MLA

al, Lisa De Lange et. "Successful application of closed loop stimulation pacemakers with remote monitoring in 3 miniature donkeys with syncope." 2021. https://doi.org/10.1111/jvim.16305.

Chicago

al, Lisa De Lange et. 2021. "Successful application of closed loop stimulation pacemakers with remote monitoring in 3 miniature donkeys with syncope.". https://doi.org/10.1111/jvim.16305.

Harvard

al, L. D. L. E. 2021, Successful application of closed loop stimulation pacemakers with remote monitoring in 3 miniature donkeys with syncope, Oxford University Press, available at: https://doi.org/10.1111/jvim.16305 [Accessed 6 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Successful application of closed loop stimulation pacemakers with remote monitoring in 3 miniature donkeys with syncope
Author / contributors
Lisa De Lange et al
Publisher
Oxford University Press
Publication year
2021
ISSN
0891-6640
ISSN
0891-6640
Language
English

Subjects

Explore related resources through these subjects.

Copied