Back to results
Bibliographic record · Consultation and access
Artículo

Estimating photoreceptor excitations from spectral outputs of a personal light exposure measurement device

Cao, Dingcai et al · Taylor & Francis · 2014

Open-access full text
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.

Resource access

Open the content from the main option or choose another available source.

CONICET Digital CONICET Digital OAI-PMH
Entrar por CONICET Digital
Main access

Open-access full text

Texto completo identificado como acceso abierto.
Open text

Summary

Descripción general del contenido del recurso.

The intrinsic circadian clock requires photoentrainment to synchronize the 24-hour solar day. Therefore, light stimulation is an important component of chronobiological research. Currently, the chronobiological research field overwhelmingly uses photopic illuminance that is based on the luminous efficiency function, V(λ), to quantify light levels. However, recent discovery of intrinsically photosensitive retinal ganglion cells (ipRGCs), which are activated by self-containing melanopsin photopigment and also by inputs from rods and cones, makes light specification using a one-dimensional unit inadequate. Since the current understanding of how different photoreceptor inputs contribute to the circadian system through ipRGCs is limited, it is recommended to specify light in terms of the excitations of five photoreceptors (S-, M-, L-cones, rods and ipRGCs). In the current study, we assessed whether the spectral outputs from a commercially available spectral watch (i.e., Actiwatch Spectrum) could be used to estimate photoreceptor excitations. Based on the color sensor spectral sensitivity functions from a previously published work, as well as from our measurements, we computed spectral outputs in the long-wavelength range (R), middle-wavelength range (G), short-wavelength range (B) and broadband range (W) under 52 CIE illuminants (25 daylight illuminants, 27 fluorescent lights). We also computed the photoreceptor excitations for each illuminant using human spectral sensitivity functions. Linear regression analyses indicated that the Actiwatch spectral outputs could predict photoreceptor excitations reliably, under the assumption of linear responses of the Actiwatch color sensors. In addition, R, G, B outputs could classify illuminant types (fluorescent vs. daylight illuminants) satisfactorily. However, the assessment of actual Actiwatch recording under several testing light sources showed that the spectral outputs were subject to great nonlinearity, leading to less accurate estimation of photoreceptor excitations. Based on our analyses, we recommend that each spectral watch should be calibrated to measure spectral sensitivity functions and linearization characteristics for each sensor to have an accurate estimation of photoreceptor excitations. The method we provided to estimate photoreceptor excitations from the outputs of spectral watches could be used for chronobiological studies that can tolerate an error in the range of 0.2-0.5 log units. Our method can be easily expanded to incorporate linearization functions to have more accurate estimations. Fil: Cao, Dingcai. University Of Illinois; Estados Unidos Fil: Barrionuevo, Pablo Alejandro. University Of Illinois; Estados Unidos. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

Cao, D. E. A. (2014). Estimating photoreceptor excitations from spectral outputs of a personal light exposure measurement device. https://nodovox.com/record.php?id=822950

MLA

Cao, Dingcai et al. "Estimating photoreceptor excitations from spectral outputs of a personal light exposure measurement device." 2014. https://nodovox.com/record.php?id=822950.

Chicago

Cao, Dingcai et al. 2014. "Estimating photoreceptor excitations from spectral outputs of a personal light exposure measurement device.". https://nodovox.com/record.php?id=822950.

Harvard

Cao, D. E. A. 2014, Estimating photoreceptor excitations from spectral outputs of a personal light exposure measurement device, Taylor & Francis, available at: https://nodovox.com/record.php?id=822950 [Accessed 9 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Estimating photoreceptor excitations from spectral outputs of a personal light exposure measurement device
Author / contributors
Cao, Dingcai et al
Publisher
Taylor & Francis
Publication year
2014
ISSN
0742-0528
ISSN
0742-0528
Language
English

Subjects

Explore related resources through these subjects.

Copied