Back to results
Bibliographic record · Consultation and access
Artículo

Variación de la Presión intraocular en función del tiempo: Contribución a la determinación del verdadero intervalo de muerte (VIM)

Gerometta, Rosana María del Rosario et al · Universidad Veracruzana. Instituto de Medicina Forense · 2019

Supplementary material available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.

Resource access

Open the content from the main option or choose another available source.

CONICET Digital CONICET Digital OAI-PMH
Entrar por CONICET Digital
Main access

Supplementary material available

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Open material

Summary

Descripción general del contenido del recurso.

Introducción: La determinación del momento del fallecimiento, es un dato de singular importancia en Medicina Legal constituyendo por su complejidad en uno de los problemas que necesita evaluación objetiva en la Patología Forense. Material y Métodos: Se propone en el presente estudio utilizar un modelo vacuno para la toma de la presión intraocular sistematizada pre y post mortem y analizar su evolución en el tiempo como posible método incruento de aproximación al Verdadero Intervalo de Muerte (VIM). Se realizó un estudio prospectivo, observacional, descriptivo con 12 vacas. Para la toma de presión intraocular (PIO) se utilizó el tonómetro manual aplanático (Perkins) calibrado previamente para bovinos. Se midió la PIO a horas establecidas posmortem. Resultados: La PIO promedio a hora 0 en OD fue de 13,48 mm Hg y de 13,59 mm Hg en OS con mínima variación entre los diferentes casos y el promedio del valor final a las 30 hr fue de 6,41 y 6,45 mm Hg en OD y OS respectivamente. Se observa una disminución de la PIO según transcurre el tiempo de muerte, de manera regular, en todos los ojos. Discusión: El hecho de la uniformidad de la disminución de la PIO en función del tiempo permite que una PIO tomada horas después de la muerte se pueda extrapolar al momento de la muerte y poder considerar la toma de la Presión Intraocular como contribución a la aproximación del verdadero intervalo de muerte (VIM). Introduction: Postmortem Interval estiamtion is a measure of singular importance in Legal Medicine. Due to its complexity, it needs objective evaluation in Forensic Pathology. Methods: In this study we propose the use of a bovine model to sytematically measure premortem and postmortem Intra-Ocular Pressure (IOP) as well as analyze its evolution with time as a possible non-invasive method to estimate PMI. A prospective, descriptive, observational study was carried out, using 12 cows. For the determination of the IOP, the aplanatic manual Perkins tonometer calibrated for bovines was used. The measurement of the IOP was done at establisehd post-mortem intervals. Results: The mean IOP at hour 0 in OD was 13.48 mm Hg and 13.59 mm Hg in OS with minimal variation between groups; at hour 30 hr, the IOP was 6.41 and 6.45 mm Hg in OD and OS respectively. We observed a decrease of the IOP in al leyes, directly related to the elapsed time of death. Discussion. The uniformity of the IOP estimations in relation to postmortem interval allows us to consider it as a valuable parameter for postmortem interval even several hours after death. Fil: Gerometta, Rosana María del Rosario. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Nordeste; Argentina. Universidad Nacional del Nordeste. Facultad de Medicina; Argentina

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

Gerometta, R. M. D. R. E. A. (2019). Variación de la Presión intraocular en función del tiempo: Contribución a la determinación del verdadero intervalo de muerte (VIM). http://hdl.handle.net/11336/105065

MLA

Gerometta, Rosana María del Rosario et al. "Variación de la Presión intraocular en función del tiempo: Contribución a la determinación del verdadero intervalo de muerte (VIM)." 2019. http://hdl.handle.net/11336/105065.

Chicago

Gerometta, Rosana María del Rosario et al. 2019. "Variación de la Presión intraocular en función del tiempo: Contribución a la determinación del verdadero intervalo de muerte (VIM).". http://hdl.handle.net/11336/105065.

Harvard

Gerometta, R. M. D. R. E. A. 2019, Variación de la Presión intraocular en función del tiempo: Contribución a la determinación del verdadero intervalo de muerte (VIM), Universidad Veracruzana. Instituto de Medicina Forense, available at: http://hdl.handle.net/11336/105065 [Accessed 8 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Variación de la Presión intraocular en función del tiempo: Contribución a la determinación del verdadero intervalo de muerte (VIM)
Author / contributors
Gerometta, Rosana María del Rosario et al
Publisher
Universidad Veracruzana. Instituto de Medicina Forense
Publication year
2019
ISSN
2448-8011
ISSN
2448-8011
Language
Spanish

Subjects

Explore related resources through these subjects.

Copied